Over here in my area the 200 amp residentails typically use 4 0 alum and some case if have to use copper for 200 amp residentails then use 2 0 but for gec all copper no alum due that size service typically have brick or cement wall and it will eat up alum conductor if not done right.
The minimum cable size for a service entrance for a 200 amp supply is.
For 215a or less you need to go to 250 000 circular mil wire.
A 100 amp electrical service will be used to supply the 98 amp load for the single family dwelling.
By nec guidelines 4 0 is required for three copper conductors carrying 195a in a tray or conduit at not more than 30 deg c ambient with insulation rated for 60 deg c.
I was told that according to electrical code a 200 amp service can t be loaded beyond 80.
Minimum service size minimum size service that should be installed is 100 a 20 circuit for very small buildings comfort stations 200 a or 225 amp 40 circuit 120 240v 1 phase for all others.
Future growth allow for future growth.
It is a 200 amp service.
2 0 copper wire ser cable mobile home feeder service entrance wires 150 ft.
In large homes 250 amp or larger service capacity may be needed particularly if the home has electric heating.
I am needing to run wire from a meter pole 260 to the service panel.
National electric code 310 315 specifies electrical services wire conductor sizes of 2 0 for copper and 4 0 for aluminum for use in 120 240 volt 3 wire single phase dwelling services and feeders.
This is going to be burried most likely in conduit and none of it will be indoors and will probably be thhn aluminum.
Take 83 amps and use the 75 c column in table 310 15 b 16 to determine that the service requires 4 awg copper type thwn overhead service entrance conductors.
This may be too small for actual load must do load calculations.
Get free shipping on qualified 200 service entrance wires or buy online pick up in store today in the electrical department.
It can supply all standard electrical needs in a typical family home buy may not support a large electric heating system.
Service entrance wires 500 kcmil thhn 6 3 se cable.
Service panel size in amps required minimum size of entrance cable in mast and meter base.
100 amps x 83 83 amps.
200 amp service is the current standard for new homes and updated service panels.
Nec requires a minimum of 100 amp 3 wire service for a single family dwelling unit.
California supply chain act.
Table of underground electrical service cable sizes amps how to detemine the electrical service size or ampacity entering a building step by step illustrated instructions how to use a dmm digital multimeter or analog voltage meters to determine or estimate service voltage and electric service and electric panel drawings for visual inspection.